Small, low-cost residential HPWH
Interactive explorer · 4758 simulated runs
← Findings report

Savings vs tank volume, zone 3, medium load

Every simulated design in this study at this zone and load size — the dashed line is the 60% VEU/ESS medium-load savings floor. A small hybrid tank (orange) reaches the same band as the large reference (grey) at a third of the volume; the spread within a colour is the above-element-fraction and element-setpoint sensitivity, not noise.

Does the top element extend V50 (maximum delivery volume)?

Appendix H maximum draw-off, Average (9°C) condition, element fitted vs removed (same tank and compressor otherwise). See the MEPS V50 tab for the Hot/Cold conditions and the draw-off trace.

Looking for the sweet spot between price, efficiency and tank size?

Every control a manufacturer actually decides — tank volume, compressor size, element capacity, element position and setpoint — precomputed across STC/savings and MEPS V50 for all 720 buildable combinations. Open the design configurator →

Current design

Drag the levers in the left panel — every table and chart here updates instantly, read straight from 720 precomputed designs.

What this design achieves

MEPS Appendix H / V50

Cost (public prices, banded; see "All designs" tab's source note)

Relative impact of each lever

Holding every other control at its current value, how much does move if you change just this one lever?

The sweet spot: price vs efficiency, by tank size

All 720 buildable designs, zone 3, medium load. Your current pick is the dark ringed dot. Points down and to the right cost more for less savings than points up and to the left — the far upper-left edge of the cloud at each colour is that tank size's own price/efficiency frontier.

Every simulated run (annual AS/NZS 4234 sweep)

The full B4 grid: 4 small-hybrid tank volumes x 4 compressor sizes x 5 element sizes x 3 element positions x 3 element setpoints, the F2/F4 comparison families, and the F1 no-element baseline. Click a row for its full design detail.

Smallest passing design per tank volume

For each volume and family, the cheapest compressor (then cheapest element) that still passes every zone's 45°C floor, zone 3's medium-load savings floor, and AS 3498 sanitation — recomputed live from the thresholds in the sidebar. Load size fixed at Medium (2), the scheme-relevant case. Bars are stacked: solid colour is the compressor, pale is the element.

MEPS Appendix H: V50 with the element fitted vs removed

Each design run through the full Appendix H maximum draw-off at all three climatic conditions (Hot 19, Average 9, Cold 1 °C), once with its element at rated power and once with the element switched to 0 kW (identical tank and compressor). V50 is the AS/NZS 5125.1 H.7.2 quantity: litres delivered above 50°C before the outlet falls through the floor. Table 15 band is the GEMS declarable load-size cap that V50 alone determines.

Maximum draw-off trace