Bosch 270L (HP 270-1E 0 FOV/S)

R134a 270 L Integral all-in-one
Bosch 270L (HP 270-1E 0 FOV/S)

Rebates up to

$520

STC $520

Replace-electric, medium household, best zone. Enter your postcode below for exact figures.

VIC Solar Homes rebate

$1,000

50% of installed price, point-of-sale. Stacks with STC/VEEC above.

VIC only. Assumed eligible, not confirmed against the live Solar Victoria product list.

Register data as at CER (STC) 2026-04-30

Specifications

Type Integral all-in-one
Refrigerant R134a
Tank volume 270 L
Rated heating capacity 1.5 kW
Rated power input 0.6 kW
COP 3.3 (EN 255-3, water inlet 15 degrees C, air 15 degrees C)
Sound level 43 dB(A)
Hot water delivery 60 °C
Operating ambient 3 to 40 °C
Tank height 1840 mm
Tank diameter 670 mm
Heat pump weight 130 kg
Electric backup 1.8 kW

Specs from: Bosch Compress 3000 DW FO installation instructions (2013, Bosch Australia); public CER SRES / VEU / ESS registers.

Certificate rebate by postcode

Enter your postcode to see the certificates and rebate for this model.

Registered certificate values

Every scheme this model is registered for, by zone. STCs at $40, VEECs at $85, ESCs at $30 (reference prices as at 2026-07-07). Claim year 2026, medium household.

SRES — STCs (national)

Zone 1 11 STCs $440
Zone 2 10 STCs $400
Sydney (Z3) 12 STCs $480
Melbourne (Z4) 13 STCs $520
Canberra (Z5) 11 STCs $440

VEU — VEECs (Victoria)

Not yet registered for VEECs.

ESS — ESCs (NSW)

Not yet registered for ESCs.

Certificate counts are computed from the model's registered performance data using the current regulated equations. A lodged claim depends on the specific installation, household size, and the scheme rules in force at creation. Energy savings % is against the AS/NZS 4234:2021 reference electric storage water heater for that zone, medium household, calculated from the model's registered performance data.

The Bosch HP 270-1E 0 FOV/S, sold as the Compress 3000 DW FO, is an integral heat pump water heater: the compressor, fan and evaporator sit in the same cabinet above a 270 L storage tank, coupled through a double wall plate heat exchanger rather than a wraparound coil. The R134a heat pump delivers 1.5 kW of heating capacity at 0.6 kW power input, giving a declared COP of 3.3 (EN 255-3, air and water inlet both at 15 degrees C). This model runs in “Heat Pump Only” mode across an ambient range of 3 to 40 degrees C, with no combined heat-pump-plus-element boost mode.

An 1.8 kW electric element (240 V) provides backup heating once the unit is powered outside that ambient range. Hot water is delivered at a fixed set point of 60 degrees C, with an outlet range of 60 to 65 degrees C, and sound pressure is 43 dBA at 2 m. The single-cabinet unit stands 1840 mm tall with a 670 mm diameter and a net weight of 130 kg.

Installation must meet AS/NZS 3500.4 (plumbing) and AS/NZS 3000 (electrical) in Australia, or Clause G12 of the New Zealand Building Code in NZ. The manual does not state a warranty period or a dedicated performance certification standard for this model.

Registered model codes

HP 270-1E 0 FOV/S

Homeowners

What's it worth at your place?

Enter your postcode to see the exact certificates and dollar rebate this model earns at your address.

Check your rebate →

Installers & retailers

Quoting this product?

Compare it against alternatives, or talk to us about eligibility, zoning and claim paperwork.

Compare models →

Manufacturers & importers

Your product?

Verify or update this listing, or ask about registering new models and maximising certificate outcomes.

Contact EnergyAE →

New to the schemes? Read how STCs, VEECs and ESCs work for residential HPWHs, or see the HPWH Intelligence Platform for live compliance and certificate tools.