Specialists in water heating design, simulation and compliance
- We simulate water heating system performance across a full year of weather and demand.
- We help manufacturers to design better products and register them for government incentives.
- We help building owners and engineers to size plant, test control strategies and decide whether a project is economically viable.
650+
Products registered
150+
Commercial systems modelled
80+
Manufacturers assisted
2
Scheme methods co-developed
Trusted by leading manufacturers, testing laboratories and certification bodies
Find your starting point
Manufacturers and importers
Getting a heat pump or solar water heater ready for the Australian and New Zealand market: test programme guidance, AS/NZS 4234 modelling, certification documents, and SRES, VEU and ESS registration.
How registration works →
Project owners and engineers
Sizing and comparing hot water plant before you commit: annual energy and running cost, lifetime cost, certificate value, control strategy, and NCC Performance Solutions for systems the deemed-to-satisfy route does not fit.
Modelling and feasibility →
Researchers and simulation users
TRNSYS 18 licences and TESS libraries from the exclusive Australian distributor, with activation and technical support, and custom models built to your brief.
TRNSYS software →Our technologies
- Heat pump water heaters
- Residential and commercial units: annual performance, design optimisation and scheme modelling.
- Solar hot water
- Thermosiphon and pumped solar thermal to AS/NZS 4234, and PV-boosted systems.
- Commercial hot water plant
- Central heat pump plant, storage, ring mains and sanitation, sized to the building's real demand.
- Controls and demand flexibility
- Time-of-use, solar soaking and demand response strategies, tested against wholesale prices and hot water delivery.
- Hydronic and water-source heat pumps
- Analysis of the scheme methods being developed to reward them in Victoria and NSW.
Our services
Compliance and incentives
From test plan to registered product. We scope AS/NZS 5125.1 testing with the laboratory, model to AS/NZS 4234 across every climate zone the schemes use, prepare certifier documentation, and lodge SRES, VEU and ESS applications through to approval. For Australian-certified products, we also map the route into New Zealand.
Modelling, energy analysis and feasibility
Annual simulation in TRNSYS and our own Python engine, checked against TRNSYS. We use it to improve product designs before tooling, compare plant options on 15-year cost, test control strategies, write NCC Performance Solutions, and advise regulators on scheme methods.
Software and tools
TRNSYS licences and support as the exclusive Australian distributor, and rebate, running-cost and sizing calculators built for manufacturers' own websites on live register data.
The path to a registered product
Five steps take a heat pump water heater from design to a registered product earning certificates. We can start at any of them, and the earlier we start, the fewer surprises at the end.
Design
Tank, refrigerant and control design reviewed for efficiency and certificate return, before tooling is committed.
Test
AS/NZS 5125.1 and 4692 test programmes scoped with the laboratory, then checked line by line.
Model
AS/NZS 4234 annual simulation in TRNSYS across every climate zone and load the schemes require.
Certify
Certifier documentation prepared and correspondence handled through to a listed certificate.
Register
SRES, VEU and ESS registrations lodged, tracked and managed to approval.
Your product earns STCs, VEECs and ESCs
Incentive schemes pay for a large share of a commercial heat pump
In Victoria (VEU Activity 44) and NSW (ESS Schedule F), a commercial heat pump water heater earns deemed certificates worth tens to hundreds of thousands of dollars per installation, particularly when it replaces electric resistance heating.
EnergyAE has modelled 150+ commercial systems. We handle testing support, TRNSYS modelling, VEU pre-registration and ESS lodgement end to end. Use our estimation tool to see how many certificates your systems could be eligible for.
Typical VEECs (VIC), replacing electric
| Capacity | Median VEECs | ≈ value |
|---|---|---|
| 30–75 kW | 335 | ~$28k |
| 75–150 kW | 937 | ~$80k |
| 150–300 kW | 2,076 | ~$176k |
| 300 kW+ | 3,966 | ~$337k |
At $85/VEEC. Based on 150+ systems modelled by EnergyAE. NSW ESS typically yields higher counts. Estimates only. Registered values require AS/NZS 4234 TRNSYS modelling.
Studies we have published
Each study comes with an interactive explorer, so you can test the result against your own case.
Commercial hot water lifetime cost
About 25,000 simulated plant-years to find the heat pump, element and storage combination that serves a fixed load at the lowest 15-year cost.
Read the study →Commercial heat pumps on a ring main
How CO2 and R290 plant registers and earns certificates under VEU Activity 44 when it serves a circulating ring main.
Read the study →Small, low-cost residential HPWH
Almost 7,000 simulated designs testing whether a small integral unit can still earn STCs, VEECs and ESCs at medium load.
Read the study →Demand response
Wholesale price and negative-price studies for water heaters, with more added as they are published.
Read the study →
Why we do this
I'm Alastair McDowell. I've always liked optimising things: work out the objective, understand the constraints, find the best design. During my Master's I bought TRNSYS from a small Sydney firm called EnergyAE, and the founder offered me a job. I spent my first years modelling solar water heaters to AS/NZS 4234, and in 2018 Chinese test laboratories started asking us to model heat pumps. That was the start of the heat pump boom.
Since then I've helped develop the VEU Activity 44 and ESS large commercial heat pump methods, and my team has modelled more than 650 registered products. What we are working towards is simple: water heaters that use the least electricity and still deliver enough hot water in the field, not only in the model. Incentives are one result of that performance.
What our clients say
Trusted by manufacturers, test laboratories and distributors across Australia, New Zealand and China.
"EnergyAE has supported us for over 10 years across a wide range of projects. Alastair has extensive knowledge of product design, engineering, and compliance within this industry, and his expertise has assisted a large number of manufacturers. I would highly recommend Alastair and EnergyAE."
Saeed Tehrani
CTO, Reclaim Energy, Apricus Australia
"EnergyAE is a very professional company. They have helped many heat pump manufacturers complete energy efficiency registrations and secure subsidies. Excellent work!"
Huang Owen
Director, CVC Testing Technology
"I've worked with EnergyAE and Alastair for around five years across energy efficiency, compliance, and scheme-related projects. Alastair is professional, extremely knowledgeable and practical, with a genuine commitment to ensuring products are properly assessed. I couldn't recommend him more highly."
Edward Schmidt
Head of R&D, Emerald Energy
The 2026 AU Residential HPWH Guide
The five steps from a design decision to a listed, incentive-eligible product across SRES, VEU and ESS, and what EnergyAE runs at each one.
The 2026 AU Commercial HPWH Guide
What large systems earn under VEU Activity 44 and ESS F16 and F17, the eligibility floors, the 2027 change in New South Wales, and the five steps to register.
Industry news, regulation updates and case studies, direct to your inbox
The EnergyAE newsletter is the fastest way to stay across what's changing in Australia and New Zealand's water heating industry.
Thanks for subscribing! You'll hear from us soon.
Something went wrong. Please try again or email us directly.
Have a product or project to model?
Book a meeting to talk through what you are building and when you need it. We will tell you what testing, modelling or analysis it needs, how long it will take and what it will cost.