Emerald Energy 200L (HPR200-1)
Rebates up to
$1,610
STC $680 · VEEC $850 (VIC) · ESC $930 (NSW)
Replace-electric, medium household, best zone. Enter your postcode below for exact figures.
AS/NZS 4234 energy savings
83%
vs the standard's reference electric storage water heater, medium household, best zone.
Register data as at CER (STC) 2026-04-30 · VEU 2026-07-01
Specifications
| Type | Integral split |
| Refrigerant | R290 |
| Tank volume | 200 L |
| Rated heating capacity | 2.8 kW |
| Rated power input | 1.15 kW |
| Sound level | 54 dB(A) |
| Hot water delivery | 55 °C |
| Operating ambient | -15 to 46 °C |
| Tank height | 1665 mm |
| Tank diameter | 505 mm |
| Heat pump weight | 27 kg |
| Tank weight (empty) | 74 kg |
| Electric backup | None (heat pump only) |
Specs from: Emerald Energy Split Air-Source Heat Pump Water Heater Installation and Owner's Manual; public CER SRES / VEU / ESS registers.
Certificate rebate by postcode
Registered certificate values
Every scheme this model is registered for, by zone. STCs at $40, VEECs at $85, ESCs at $30 (reference prices as at 2026-07-07). Claim year 2026, medium household.
SRES — STCs (national)
| CER Zone 1 | 13 STCs | $520 |
| CER Zone 2 | 13 STCs | $520 |
| CER Zone 3 | 15 STCs | $600 |
| CER Zone 4 | 17 STCs | $680 |
| CER Zone 5 | 17 STCs | $680 |
VEU — VEECs (Victoria)
| Zone | Repl. electric metro / regional | Repl. gas | Energy savings |
|---|---|---|---|
| VEU Zone 4 | 9 / 10 | 9 | 82.8% |
| VEU Zone 5 | 9 / 10 | 8 | 82.6% |
ESS — ESCs (NSW)
| Zone | Repl. electric metro / regional | Repl. gas metro / regional | Energy savings |
|---|---|---|---|
| ESS Zone 3 | 27 / 28 | 13 / 13 | 74.9% |
| ESS Zone 5 | 30 / 31 | 15 / 14 | 74.8% |
Certificate counts are computed from the model's registered performance data using the current regulated equations. A lodged claim depends on the specific installation, household size, and the scheme rules in force at creation. Energy savings % is against the AS/NZS 4234:2021 reference electric storage water heater for that zone, medium household, calculated from the model's registered performance data.
The Emerald Energy HPR200-1 is a split-system heat pump water heater: an R290 outdoor heat pump unit connects to a 200 L tank by pre-charged quick-connect refrigerant couplings, so the refrigerant cycle heats the tank directly. The outdoor unit delivers 2.8 kW of heating with a 1.15 kW power input (at 19/15 degrees C DB/WB ambient, 9 degrees C initial water heated to 70 degrees C), and runs in ambient temperatures from -15 to 46 degrees C.
This variant has no electric backup element. Hot water is delivered at a default 55 degrees C, and the same outdoor heat pump unit is shared across the 200 L and 300 L tank sizes in this range.
The HPR200 and HPR200-1 register strings appear to be the same physical product across production revisions; the manual itself only names the HPR200-1 model number.
Registered model codes
HPR200, HPR200-1
Homeowners
What's it worth at your place?
Enter your postcode to see the exact certificates and dollar rebate this model earns at your address.
Check your rebate →Installers & retailers
Quoting this product?
Compare it against alternatives, or talk to us about eligibility, zoning and claim paperwork.
Compare models →Manufacturers & importers
Your product?
Verify or update this listing, or ask about registering new models and maximising certificate outcomes.
Contact EnergyAE →New to the schemes? Read how STCs, VEECs and ESCs work for residential HPWHs, or see the HPWH Intelligence Platform for live compliance and certificate tools.