Stiebel Eltron 220L (WWK 222 H) - NZ
AS/NZS 4234 energy savings (AU equivalent)
69%
vs the standard's reference electric storage water heater, ESS Zone 3, based on the AU-registered performance of the Stiebel Eltron 220L (WWK 222 H) (identical model code WWK 222 H and brand, sold in both AU and NZ; the German-engineered unit is the same global product in both markets) — not tested against AS/NZS 4234 as a NZ product itself.
Specifications
| Type | Integral all-in-one |
| Refrigerant | R134a |
| Tank volume | 220 L |
| Rated power input | 0.5 kW |
| COP | 3.94 (Annual Average COP, AS/NZS 4234, climate zone 2, medium load (AU test data for the identical unit)) |
| Sound level | 45 dB(A) |
| Hot water delivery | 61 °C |
| Operating ambient | -5 to 42 °C |
| Tank height | 1501 mm |
| Tank diameter | 690 mm |
| Tank weight (empty) | 120 kg |
| Electric backup | 1.5 kW |
| Warranty | Cylinder/condenser 5, sealed refrigeration system 2, T&P relief valve 1 (domestic use) |
Specs from: Stiebel Eltron New Zealand product page (stiebel-eltron.co.nz/wwk); specs cross-referenced from the identical AU-registered WWK 222 H operation and installation manual. Official product page →
Sold in New Zealand
NZ has no equivalent to the Australian STC/VEEC/ESC certificate schemes, so no dollar rebate applies to this model. Its confirmed AU-market equivalent is registered and shown above.
The Stiebel Eltron WWK 222 H is an all-in-one integral heat pump water heater sold under the same brand and model code in New Zealand and Australia: the R134a heat pump sits in the upper section of the cabinet directly above a 220 L DHW cylinder, with no separate outdoor unit or field refrigerant piping. Stiebel Eltron NZ markets the WWK range as saving up to 74% on hot water energy use compared to a traditional electric cylinder.
Average power consumption of the heat pump at the A15/W10-55 test condition is 0.5 kW, and the heat pump operates down to -5 degrees C ambient, up to +42 degrees C. Annual Average Coefficient of Performance under AS/NZS 4234 (climate zone 2, medium load) is 3.94, per the AU test data for the identical unit; New Zealand has no equivalent mandated test standard.
A 1.5 kW electric emergency/booster heater backs up the heat pump outside the application limits, lifting the cylinder to a maximum of 65 degrees C; the heat pump alone reaches a default set temperature of 61 degrees C. The unit stands 1501 mm tall, 690 mm in diameter, and weighs 120 kg empty.
Homeowners
What's it worth at your place?
Enter your postcode to see the exact certificates and dollar rebate this model earns at your address.
Check your rebate →Installers & retailers
Quoting this product?
Compare it against alternatives, or talk to us about eligibility, zoning and claim paperwork.
Compare models →Manufacturers & importers
Your product?
Verify or update this listing, or ask about registering new models and maximising certificate outcomes.
Contact EnergyAE →New to the schemes? Read how STCs, VEECs and ESCs work for residential HPWHs, or see the HPWH Intelligence Platform for live compliance and certificate tools.