Stiebel Eltron 302L (WWK 302) - NZ
AS/NZS 4234 energy savings (AU equivalent)
68%
vs the standard's reference electric storage water heater, ESS Zone 3, based on the AU-registered performance of the Stiebel Eltron 302L (WWK 302) (identical model code WWK 302 and brand, sold in both AU and NZ; the German-engineered unit is the same global product in both markets) — not tested against AS/NZS 4234 as a NZ product itself.
Specifications
| Type | Integral all-in-one |
| Refrigerant | R134a |
| Tank volume | 302 L |
| Rated power input | 0.5 kW |
| COP | 3.58 (Annual Average COP, AS/NZS 4234, climate zone 2, medium load (AU test data for the identical unit)) |
| Sound level | 45 dB(A) |
| Hot water delivery | 61 °C |
| Operating ambient | -5 to 42 °C |
| Tank height | 1905 mm |
| Tank diameter | 690 mm |
| Tank weight (empty) | 135 kg |
| Electric backup | None (heat pump only) |
| Warranty | Cylinder/condenser 5, sealed refrigeration system 2, T&P relief valve 1 (domestic use) |
Specs from: Stiebel Eltron New Zealand product page (stiebel-eltron.co.nz/wwk); specs cross-referenced from the identical AU-registered WWK 302 operation and installation manual. Official product page →
Sold in New Zealand
NZ has no equivalent to the Australian STC/VEEC/ESC certificate schemes, so no dollar rebate applies to this model. Its confirmed AU-market equivalent is registered and shown above.
The Stiebel Eltron WWK 302 is an all-in-one integral heat pump water heater sold under the same brand and model code in New Zealand and Australia: the R134a heat pump sits in the upper section of the cabinet directly above a 302 L DHW cylinder, with no separate outdoor unit or field refrigerant piping. Stiebel Eltron NZ markets the WWK 302 as designed to operate down to -5 degrees C with an active defrost function for cold-climate reliability.
Average power consumption of the heat pump at the A15/W10-55 test condition is 0.5 kW. Annual Average Coefficient of Performance under AS/NZS 4234 (climate zone 2, medium load) is 3.58, per the AU test data for the identical unit; New Zealand has no equivalent mandated test standard.
The WWK 302 has no electric emergency/booster heater: DHW heating relies solely on the heat pump, which reaches a default set temperature of 61 degrees C. The unit stands 1905 mm tall, 690 mm in diameter, and weighs 135 kg empty. The WWK 302 H shares the same 302 L cabinet but adds an electric emergency/booster heater.
Homeowners
What's it worth at your place?
Enter your postcode to see the exact certificates and dollar rebate this model earns at your address.
Check your rebate →Installers & retailers
Quoting this product?
Compare it against alternatives, or talk to us about eligibility, zoning and claim paperwork.
Compare models →Manufacturers & importers
Your product?
Verify or update this listing, or ask about registering new models and maximising certificate outcomes.
Contact EnergyAE →New to the schemes? Read how STCs, VEECs and ESCs work for residential HPWHs, or see the HPWH Intelligence Platform for live compliance and certificate tools.