Viessmann 190L (Vitocal 151-A 151.A16)
Rebates up to
$560
STC $560
Replace-electric, medium household, best zone. Enter your postcode below for exact figures.
Register data as at CER (STC) 2026-04-30
Specifications
| Type | Standalone split |
| Refrigerant | R290 |
| Tank volume | 190 L |
| Rated heating capacity | 9.1 kW |
| Rated power input | 1.86 kW |
| COP | 4.9 (EN 14511, A7/W35, 5K spread) |
| Sound level | 56 dB(A) |
| Hot water delivery | 60 °C |
| Heat pump weight | 197 kg |
| Tank weight (empty) | 170 kg |
| Electric backup | 2.4 kW |
Certified to
Specs from: Viessmann Vitocal 151-A installation and service instructions (6199682, 8/2024); public CER SRES register.
Certificate rebate by postcode
Registered certificate values
Every scheme this model is registered for, by zone. STCs at $40, VEECs at $85, ESCs at $30 (reference prices as at 2026-07-07). Claim year 2026, medium household.
SRES — STCs (national)
| CER Zone 1 | 11 STCs | $440 |
| CER Zone 2 | 11 STCs | $440 |
| CER Zone 3 | 13 STCs | $520 |
| CER Zone 4 | 14 STCs | $560 |
| CER Zone 5 | 14 STCs | $560 |
VEU — VEECs (Victoria)
Not yet registered for VEECs.
ESS — ESCs (NSW)
Not yet registered for ESCs.
Certificate counts are computed from the model's registered performance data using the current regulated equations. A lodged claim depends on the specific installation, household size, and the scheme rules in force at creation. Energy savings % is against the AS/NZS 4234:2021 reference electric storage water heater for that zone, medium household, calculated from the model's registered performance data.
The Vitocal 151-A 151.A16 is a monoblock air source heat pump: an R290 (propane) outdoor unit connected by heating water pipework to an indoor unit with a 190 L DHW cylinder integrated in the same cabinet. The heat pump also serves up to four heating or cooling circuits, so the indoor unit doubles as a space heating and cooling generator, with the DHW cylinder heated indirectly off the same heating water loop rather than by direct refrigerant contact.
At the EN 14511 A7/W35 rating point the A16 delivers 9.1 kW heating output for 1.86 kW power input, a COP of 4.9. A 2.4 kW single-phase instantaneous heating water heater is built into the indoor unit as backup, and DHW temperature is limited to 60 degrees C. Outdoor unit sound power is 56 dB(A) (ErP), rising to 66 dB(A) at maximum and dropping to 59 dB(A) in low-noise mode.
The outdoor unit is offered with a 400 V three-phase supply (AWOT-E-AC-AF) or a 230 V single-phase supply (AWOT-M-E-AC-AF); both use the same refrigerant circuit, indoor unit, and performance data. Certificate values below are the same across those variants.
Registered model codes
Vitocal 151-A AWOT-E-AC-AF 151.A16, Vitocal 151-A AWOT-M-E-AC-AF 151.A16
Homeowners
What's it worth at your place?
Enter your postcode to see the exact certificates and dollar rebate this model earns at your address.
Check your rebate →Installers & retailers
Quoting this product?
Compare it against alternatives, or talk to us about eligibility, zoning and claim paperwork.
Compare models →Manufacturers & importers
Your product?
Verify or update this listing, or ask about registering new models and maximising certificate outcomes.
Contact EnergyAE →New to the schemes? Read how STCs, VEECs and ESCs work for residential HPWHs, or see the HPWH Intelligence Platform for live compliance and certificate tools.