ESS IHEAB: Commercial HPWH F16/F17 [ESC]

Every commercial heat pump water heater system accepted on the NSW Energy Savings Scheme registry, with the ESCs it creates under the IHEAB method. Switch between replacing gas, replacing electric and a new install, and filter by system size.

Systems are registered against a commercial peak load, so the largest numbers here simply belong to the largest systems. Use the peak load filter to compare systems of a similar size.

What does the heat pump replace?

Decommission an existing gas water heater or boiler serving a commercial building.

Brands

Sets your zone and network region.

EnergyAE reference price.

Network region
Peak load (MJ/day)
to

Where the new heat pump is larger than the system it replaces, both schemes scale the certificates by existing ÷ new. Leave blank to assume matched capacity. The register does not publish each model’s rated capacity, so this applies to every row equally.

EnergyAE reference ESC price, reviewed 2026-07-07 (live market feed unavailable). Edit to model a different price.
Models listed
351
of 364 on this board
Brands
42
42 registered
Sydney (Z3) range
8 to 3,273
Median 14 ESCs
Median value at $30/ESC
$420
Per installation, replace gas

How the register is spread in Sydney (Z3)

every registered model

Scroll the table sideways to see every zone.

#
13,27314,865
23,0572,9288,581
32,9792,7378,280
42,9462,7408,189
52,6112,4347,439
62,5332,4177,097
72,4832,3096,933
82,3152,3226,852
92,3042,2237,148
102,1612,1186,198
112,0861,7748,261
122,0321,7507,645
131,9041,6296,495
141,8991,8055,408
151,8031,5677,265
161,7841,8005,196
171,7681,6234,938
181,6931,5515,165
191,6901,5914,788
201,6671,3336,674
211,6647,435
221,6611,6014,744
231,5751,5054,520
241,5611,4714,818
251,5056,777
261,4971,2805,174
271,4951,5244,562
281,3871,2973,870
291,3061,2673,828
301,3021,0275,050
311,2911,1663,625
321,2555,933
331,2401,1763,439
341,2375,718
351,2039934,247
361,2015,604
371,1839565,364
381,1809224,667
399809382,798
409774,229
419237513,875
429188522,556
439007833,629
448868652,572
458647323,039
466775772,550
476252,957
486156411,889
496114972,521
506012,761
515912,716
525904632,309
535674422,269
545632,450
555574262,228
565205031,483
575165171,502
584954711,380
594551,988
604384051,247
61213114760
62213114760
63213114760
64213114760
6519582690
6619582690
6719582690
6819582690
691916103
701916103
711816123
721815104
731815104
741715113
75171597
76171597
771716105
781716105
791715136
801715136
8117111,400
821711220
831711280
841711327
851711420
861711440
871711560
881711840
8917111,120
9017151,370
911715274
921715411
931715548
941715822
9517151,096
961711140
971715137
981711110
991716240
1001716243
Showing 100 of 351

Every figure is computed from the ESS Registry of accepted products, read on each site build (2026-09-22). This registry does not publish a snapshot date of its own. Certificates are created per zone against the one climate zone an installation sits in, so the zone columns are alternatives and there is no total to read across them. Sort by the zone you are installing in.

How these numbers are calculated

ESS Rule of 2009 Schedule F, Activities F16 and F17. Gas and electricity savings are each taken over a 12-year lifetime, converted at 3.6 GJ/MWh, then weighted by GasCCF 0.47 and ElecCCF 1.06, with the regional network factor 1.03 applied to the electricity term only.

RefElec = 365 × 0.905 × 1.05 × CPL ÷ 1000, the same commercial peak load basis as the VEU. The replaced-system efficiency is 0.788 and a new install is credited against 0.85.

CapacityFactor applies to F16 only: 1 where the new heat pump is no larger than the system it replaces, otherwise existing ÷ new.

Counts are capped at 5,000 certificates per item of end-user equipment (clause 9.9.5). Clause 9.9.1C treats heat pumps joined by manifold into one system as a single item, so the cap applies per system.

The ConfidenceFactor is 42 ÷ Peak Load, capped at 1, wherever a system’s average heat pump capacity (total capacity ÷ number of heat pumps) is below 10 kW, and it applies to F16 and F17. Note it carries no N, unlike the VEU LoadFactor, so it cuts a multi-heat-pump system several times harder. It is applied wherever the register row publishes a heat pump thermal capacity and heat pump count, and skipped and disclosed where it does not.

Products are listed under the brand and model number they carry on the register, which is not always the name a product is sold under. Source: ESS Registry of accepted products.

These are estimates for comparison and business-case purposes. A lodged claim depends on the installation, its climate zone, the product’s eligibility on the day the certificates are created, and the scheme rules then in force.

Your product is not on the register yet

Getting a heat pump water heater onto these registers means AS/NZS 4234 modelling, AS/NZS 2712 certification and a scheme application. We run that process end to end for manufacturers and importers.

Request a quote

Your product is listed and the figures look wrong

A registered figure reflects the system as it was modelled and declared, including its control settings and tank configuration. If it does not match how the unit is built or sold, that is worth looking at.

Talk to our team →