Annual Simulations

How to run annual simulations with TRNSYS Tool.

Pre-Simulation

Finalize all parameters and control settings before proceeding.

Configuration

Zone ranges:

  • CER: zones 1–5
  • VEU/ESS: zones 3–5

Load size:

  • CER: load 2 only
  • VEU/ESS: loads 1–2

AS/NZS 4234 version:

  • SRES/CER: 2008
  • VEU/ESS: 2021

Load Size and Version Matrix

Load SizeAS/NZS 4234:2008AS/NZS 4234:2021
Load 1 (small)VEU 1D/3C* (zones 4–5)
Load 2 (medium)SRES/CER (zones 1–5)ESS D17/D19 (zones 3, 5)

*VEU 1D/3C must meet 60% energy savings and minimum delivery temperature for load 2, but earns certificates based on load 1 results.

Run Simulations

Timestep: Use 0.02. Reduce to 0.01 or 0.005 only if convergence fails — check parameters first.

Model range: Verify that column numbers correspond to model numbers in row 5.

Click “Run” to start simulations.

Review Results

  1. Navigate to the “Res_Results” sheet when simulations complete.
  2. Click “Clear” then “Import” to populate results.
  3. Check that MDT ≥ 45.0 and energy savings ≥ 60.0% (for load 2).

MDT below 45? Reduce HP deadband (Tdb_HP) and re-run.

Energy savings note: Load 1 does not require 60% savings; load 2 does.